Modbus Keyword ============== The modbus keyword can be used for matching on various properties of Modbus requests. There are three ways of using this keyword: * matching on functions properties with the setting "function"; * matching on directly on data access with the setting "access"; * matching on unit identifier with the setting "unit" only or with the previous setting "function" or "access". With the setting **function**, you can match on: * an action based on a function code field and a sub-function code when applicable; * one of three categories of Modbus functions; * public functions that are publicly defined (setting "public") * user-defined functions (setting "user") * reserved functions that are dedicated to proprietary extensions of Modbus (keyword "reserved") * one of the two sub-groups of public functions: * assigned functions whose definition is already given in the Modbus specification (keyword "assigned"); * unassigned functions, which are reserved for future use (keyword "unassigned"). Syntax:: modbus: function modbus: function , subfunction modbus: function [!] Sign '!' is negation Examples:: modbus: function 21 # Write File record function modbus: function 4, subfunction 4 # Force Listen Only Mode (Diagnostics) function modbus: function assigned # defined by Modbus Application Protocol Specification V1.1b3 modbus: function public # validated by the Modbus.org community modbus: function user # internal use and not supported by the specification modbus: function reserved # used by some companies for legacy products and not available for public use modbus: function !reserved # every function but reserved function With the **access** setting, you can match on: * a type of data access (read or write); * one of primary tables access (Discretes Input, Coils, Input Registers and Holding Registers); * a range of addresses access; * a written value. Syntax:: modbus: access modbus: access read modbus: access read , address modbus: access write < coils | holding> modbus: access write < coils | holding>, address modbus: access write < coils | holding>, address , value With __ setting matches on the address or value as it is being accessed or written as follows:: address 100 # exactly address 100 address 100<>200 # greater than address 100 and smaller than address 200 address >100 # greater than address 100 address <100 # smaller than address 100 Examples:: modbus: access read # Read access modbus: access write # Write access modbus: access read input # Read access to Discretes Input table modbus: access write coils # Write access to Coils table modbus: access read discretes, address <100 # Read access at address smaller than 100 of Discretes Input table modbus: access write holding, address 500, value >200 # Write value greater than 200 at address 500 of Holding Registers table With the setting **unit**, you can match on: * a MODBUS slave address of a remote device connected on the sub-network behind a bridge or a gateway. The destination IP address identifies the bridge itself and the bridge uses the MODBUS unit identifier to forward the request to the right slave device. Syntax:: modbus: unit modbus: unit , function modbus: unit , function , subfunction modbus: unit , function [!] modbus: unit , access modbus: unit , access read modbus: unit , access read , address modbus: unit , access write < coils | holding> modbus: unit , access write < coils | holding>, address modbus: unit , access write < coils | holding>, address , value With __ setting matches on the address or value as it is being accessed or written as follows:: unit 10 # exactly unit identifier 10 unit 10<>20 # greater than unit identifier 10 and smaller than unit identifier 20 unit >10 # greater than unit identifier 10 unit <10 # smaller than unit identifier 10 Examples:: modbus: unit 10 # Unit identifier 10 modbus: unit 10, function 21 # Unit identifier 10 and write File record function modbus: unit 10, function 4, subfunction 4 # Unit identifier 10 and force Listen Only Mode (Diagnostics) function modbus: unit 10, function assigned # Unit identifier 10 and assigned function modbus: unit 10, function !reserved # Unit identifier 10 and every function but reserved function modbus: unit 10, access read # Unit identifier 10 and Read access modbus: unit 10, access write coils # Unit identifier 10 and Write access to Coils table modbus: unit >10, access read discretes, address <100 # Greater than unit identifier 10 and Read access at address smaller than 100 of Discretes Input table modbus: unit 10<>20, access write holding, address 500, value >200 # Greater than unit identifier 10 and smaller than unit identifier 20 and Write value greater than 200 at address 500 of Holding Registers table (cf. http://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf) **Note:** Address of read and write are starting at 1. So if your system is using a start at 0, you need to add 1 the address values. **Note:** According to MODBUS Messaging on TCP/IP Implementation Guide V1.0b, it is recommended to keep the TCP connection opened with a remote device and not to open and close it for each MODBUS/TCP transaction. In that case, it is important to set the depth of the stream reassembling as unlimited (stream.reassembly.depth: 0) **Note:** According to MODBUS Messaging on TCP/IP Implementation Guide V1.0b, the MODBUS slave device addresses on serial line are assigned from 1 to 247 (decimal). Address 0 is used as broadcast address. (cf. http://www.modbus.org/docs/Modbus_Messaging_Implementation_Guide_V1_0b.pdf) Paper and presentation (in french) on Modbus support are available : http://www.ssi.gouv.fr/agence/publication/detection-dintrusion-dans-les-systemes-industriels-suricata-et-le-cas-modbus/